iCE Consumables and Reagents
Frequently Ordered Items
ProteinSimple provides a series of reagents and consumables for use with the iCE3 and iCE280 Systems. Please contact us at orders@proteinsimple.com for pricing and order information. iCE system kits and reagents expire 12 months after the date of manufacture.
Cartridge Kits
The new HT Cartridge analyzes samples in 10 minutes with comparable results to the original FC (cIEF) Cartridge, and eliminates the need for methyl cellulose in sample mixtures. The original FC Cartridge requires methyl cellulose in both the rinse and sample solutions.
| Part # | Description | Qty/Amt |
|---|---|---|
| 101701 | FC Cartridge (original cIEF cartridge) | 2/pkg |
| P-0000035-00 | HT Cartridge | 2/pkg |
Note: The HT Cartridge can be used on both iCE3 and iCE280 systems. However, the HT Cartridge was optimized and validated for iCE3 with iCE CFR Software version 4.0.
Chemical Test Kits
Designed to confirm the overall performance of iCE systems on three separate occasions. Kits are available for both the FC and HT cartridges.
| Part # | Description | |
|---|---|---|
| 101801 | FC Cartridge Chemical Test Kit. The kit contains anolyte, catholyte, 0.5% methyl cellulose, a hemoglobin stock solution and three vials of a standard solution composed of carrier ampholytes and pI markers in 0.35% methyl cellulose. | |
| P-0000033-00 | HT Cartridge Chemical Test Kit. The kit contains anolyte, catholyte, 0.5% methyl cellulose, a hemoglobin stock solution and three vials of a standard solution composed of carrier ampholytes and pI markers in deionized water. | |
Electrolyte Kit
Simplifies system setup with pre-made analytical grade electrolyte solutions. This kit is suitable for both the original FC and the new HT cIEF cartridges.
| Part # | Description | |
|---|---|---|
| 102506 | The kit includes 1 x 100 mL bottle of 0.08 M phosphoric acid in 0.1% methyl cellulose and 1 x 100 mL bottle of 0.1 M sodium hydroxide in 0.1% methyl cellulose. | |
0.5% Methyl Cellulose Kit
Required for capillary rinsing between injections to minimize electroosmotic flow. This kit is suitable for both the original FC and the new HT cIEF cartridges.
| Part # | Description | |
|---|---|---|
| 102505 | Conveniently packaged in 2 x 100 mL bottles, and solution viscosity is tested to ensure consistency. | |
System Suitability Kits
Provides a convenient method of checking the performance of iCE systems on 10 separate occasions. Once prepared, each test solution is stable for three days. Kits are available for both the FC and HT cartridges.
| Part # | Description | |
|---|---|---|
| 102093 | FC Cartridge System Suitability Kit. The kit includes a hemoglobin stock solution and 10 vials of a standard solution composed of carrier ampholytes and pI markers in 0.35% methyl cellulose. | |
| P-0000034-00 | HT Cartridge System Suitability Kit. The kit includes a hemoglobin stock solution and 10 vials of a standard solution composed of carrier ampholytes and pI markers in deionized water. | |
1% Methyl Cellulose Kit
Required for maintaining sample viscosity and is required for the FC Cartridge only.
| Part # | Description | |
|---|---|---|
| 101876 | Kit includes 1 x 100 mL bottle of 1.0% methyl cellulose and is tested to ensure consistency. | |
TTM Solution Kits
Accurate transfer time measurements provide reproducible data while minimizing sample consumption. Kits can be used for approximately 150 measurements and are available for both the FC and HT cartridges.
| Part # | Description | |
|---|---|---|
| 102672 | FC Cartridge Transfer Time Measurement Kit. This kit enables consistent and precise measurement of transfer time using the original FC cIEF Cartridge. Contains 2 x 8 mL bottles. | |
| P-0000037-00 | HT Cartridge Transfer Time Measurement Kit. This kit enables consistent and precise measurement of transfer time using the HT cIEF Cartridge only. Contains 2 x 8 mL bottles. | |
Cartridge Wash Kit
Allows proper washing and storage of the FC and HT cIEF cartridges.
| Part # | Description | |
|---|---|---|
| 045-207 | Kit includes instructions for capillary rinsing and storage. | |
pI Markers
A new series of small molecule pI Markers with assigned pI values, designed to provide consistent and accurate results. The pI Markers may be used for whole-column and single-point capillary isoelectric focusing (cIEF) detection to measure a sample's isoelectric point and to perform quality control of sample analysis. Each pI Marker comes in a vial with 200 µL of stock solution.
| Part # | pI Value |
|---|---|
| 102221 | 2.85 |
| 102018 | 3.21 |
| 102222 | 3.59 |
| 102350 | 4.22 |
| 102223 | 4.65 |
| 102224 | 5.12 |
| 102225 | 5.85 |
| 102220 | 6.14 |
| 102409 | 6.61 |
| 102226 | 7.05 |
| 102227 | 7.40 |
| 102170 | 7.55 |
| 102407 | 7.65 |
| 102171 | 7.90 |
| 102408 | 8.18 |
| 102229 | 8.40 |
| 102230 | 8.79 |
| 102231 | 9.22 |
| 102349 | 9.46 |
| 101996 | 9.50 |
| 102219 | 9.77 |
| 102232 | 10.10 |
| 102233 | 10.45 |